Digital pulse-shape analysis with a TRACE early silicon prototype
2014
[EN] A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 tun thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination. K.; 2014 Elsevier B.V. All rights reserved
The SAGE spectrometer: A tool for combined in-beam gamma-ray and conversion electron spectroscopy
2010
International audience; The sage spectrometer allows simultaneous in-beam -ray and internal conversion electron measurements, by combining a germanium detector array with a highly segmented silicon detector and an electron transport system. sage is coupled with the ritu gas- lled recoil separator and the great focal-plane spectrometer for recoil-decay tagging studies. Digital electronics are used both for the ray and the electron parts of the spectrometer. sage was commissioned in the Accelerator Laboratory of the University of Jyvaskyla in the beginning of 2010.
α -decay spectroscopy of the N=130 isotones Ra218 and Th220 : Mitigation of α -particle energy summing with implanted nuclei
2019
© 2019 American Physical Society. An analysis technique has been developed in order to mitigate energy summing due to sequential short-lived α decays from nuclei implanted into a silicon detector. Using this technique, α-decay spectroscopy of the N=130 isotones Ra218 (Z=88) and Th220 (Z=90) has been performed. The energies of the α particles emitted in the Ra218→Rn214 and Th220→Ra216 ground-state-to-ground-state decays have been measured to be 8381(4) keV and 8818(13) keV, respectively. The half-lives of the ground states of Ra218 and Th220 have been measured to be 25.99(10) μs and 10.4(4) μs, respectively. The half-lives of the ground states of the α-decay daughters, Rn214 and Ra216, have …
DEPFET pixel detector in the Belle II experiment
2019
Belle II DEPFET and PXD Collaboration: et al.
Irradiated silicon detectors for HL-LHC: Characterization and simulations
2012
283 páginas. Tesis Doctoral del Departamento de Física Atómica, Molecular y Nuclear, de la Universidad de Valencia. Fecha de lectura: 18 julio 2012.
Measurements of Low-Energy Protons using a Silicon Detector for Application to SEE Testing
2021
A silicon detector with a fast electronics chain is used for the dosimetry of protons in the range 0.5-5 MeV at the Centro Nacional de Aceleradores (CNA) 3 MV Tandem laboratory in Seville, Spain. In this configuration, measurements can be performed in pulsed mode, using a digitizer to record event-by-event proton energy depositions. The distributions of deposited energy were obtained thanks to a calibration with an alpha source. Measurements of flux and deposited energy are used to enable single event effect (SEE) testing on selected static random access memories (SRAMs).
Determination of absolute internal conversion coefficients using the SAGE spectrometer
2016
A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of 154Sm, 152Sm and 166Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for …
The LOFT mission concept: a status update
2016
The Large Observatory For x-ray Timing (LOFT) is a mission concept which was proposed to ESA as M3 and M4 candidate in the framework of the Cosmic Vision 2015-2025 program. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument and the uniquely large field of view of its wide field monitor, LOFT will be able to study the behaviour of matter in extreme conditions such as the strong gravitational field in the innermost regions close to black holes and neutron stars and the supra-nuclear densities in the interiors of neutron stars. The science payload is based on a Large Area Detector (LAD, >8m2 effective area, 2-30 keV, 240 eV spectral resolut…
A position sensitive β−γ coincidence technique for sample analysis with the upgraded PANDA device
2020
Abstract PANDA (Particles And Non-Destructive Analysis) is measuring system developed for non-destructive analysis of samples for safety, security and safeguards. The capabilities of the PANDA device were expanded by the addition of a thick silicon detector for β particle detection. The upgraded device can now be used for position-sensitive α − γ and β − γ coincidence measurements of various kinds of radioactive samples. The capability of the PANDA device in using the β − γ coincidence technique was tested using a mixed source of 134Cs and 226Ra. In addition, the ability of PANDA to locate nuclides emitting β particles from samples was tested using a combined sample containing a mixed 134Cs…
Detector-electrode for alpha spectrometry in water sample, numerical and early feasibility investigation toward thermocompression bonding assembly pr…
2020
International audience; This study focuses on the feasibility of a detector-electrode for direct alpha measurement in aqueous samples. Such a device could be made by adding a boron doped diamond electrode on top of a standard silicon detector, with bonding and insulating layers. The impact of these different layers has been investigated by Monte-Carlo simulation (MCNP6), to find a compromise between alpha detection of the silicon, electrode and shielding properties of the diamond. The assembly process involving thermocompression between both substrates was successfully achieved under a clean room conditions.